suits any manufacturer of fans
450mm dia Flange used to bolt directly to any manufacturer of Fans, as part of a full ancillary package or for the fan to mount inline in ducting.
This flange is unique because it is designed to fix to UK and European PCD detail, meaning this flange will fix to any manufacturers fans
Can also be used to fix directly to a Silencer
Can also be used to fix directly to ducting
Manufactured from pre Galvanised sheet
450mm Flexible connection, used to fit to Flanges (with spigots), Silencers (with spigots) or spiral ducting.
A flexible connection is used to isolate the fan from the system to prevent vibration transfer and helps minimise noise transfer through fixings or structures.
It can also be used to simplify installation by bridging any small gaps between sections of the installation, for example the gap between a fan and the ductwork
The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
149-EL21 suitable for a maximum full load of 1.5 amps
149-EL31 suitable for a maximum full load of 3 amps
149-EL31TK suitable for a maximum full load of 3 amps *
149-EL41 suitable for a maximum full load of 4 amps
149-EL61 suitable for a maximum full load of 6 amps
149-EL61TK suitable for a maximum full load of 6 amps *
149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
Flakt Woods
The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
149-EL21 suitable for a maximum full load of 1.5 amps
149-EL31 suitable for a maximum full load of 3 amps
149-EL31TK suitable for a maximum full load of 3 amps *
149-EL41 suitable for a maximum full load of 4 amps
149-EL61 suitable for a maximum full load of 6 amps
149-EL61TK suitable for a maximum full load of 6 amps *
149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
Flakt Woods
Ziehl Abegg
Elta
Helios
Solar and Palau
Nuaire
Systemair
Vent-Axia
Roof Units
The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
149-EL21 suitable for a maximum full load of 1.5 amps
149-EL31 suitable for a maximum full load of 3 amps
149-EL31TK suitable for a maximum full load of 3 amps *
149-EL41 suitable for a maximum full load of 4 amps
149-EL61 suitable for a maximum full load of 6 amps
149-EL61TK suitable for a maximum full load of 6 amps *
149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
Flakt Woods
Ziehl Abegg
Elta
Helios
Solar and Palau
Nuaire
Systemair
Vent-Axia
Roof Units
The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
149-EL21 suitable for a maximum full load of 1.5 amps
149-EL31 suitable for a maximum full load of 3 amps
149-EL31TK suitable for a maximum full load of 3 amps *
149-EL41 suitable for a maximum full load of 4 amps
149-EL61 suitable for a maximum full load of 6 amps
149-EL61TK suitable for a maximum full load of 6 amps *
149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
Flakt Woods
Ziehl Abegg
Elta
Helios
Solar and Palau
Nuaire
Systemair
Vent-Axia
Roof Units
The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
149-EL21 suitable for a maximum full load of 1.5 amps
149-EL31 suitable for a maximum full load of 3 amps
149-EL31TK suitable for a maximum full load of 3 amps *
149-EL41 suitable for a maximum full load of 4 amps
149-EL61 suitable for a maximum full load of 6 amps
149-EL61TK suitable for a maximum full load of 6 amps *
149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
Flakt Woods
Ziehl Abegg
Elta
Helios
Solar and Palau
Nuaire
Systemair
Vent-Axia
Roof Units
The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
149-EL21 suitable for a maximum full load of 1.5 amps
149-EL31 suitable for a maximum full load of 3 amps
149-EL31TK suitable for a maximum full load of 3 amps *
149-EL41 suitable for a maximum full load of 4 amps
149-EL61 suitable for a maximum full load of 6 amps
149-EL61TK suitable for a maximum full load of 6 amps *
149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
Flakt Woods
Ziehl Abegg
Elta
Helios
Solar and Palau
Nuaire
Systemair
Vent-Axia
Roof Units
The Elta Compact SCPP is a 1phase two stage axial fan specifically developed for high pressure requirements not suited to single stage fans. The fans have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing.
Features
Available in 3 sizes 500/560/630 all stocked
The fan can be installed at any angle
Suitable for internal and external use
500dia and 560dia suitable for speed control
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and +50°C when used with a speed controller.
Adjustable pitch aerofoil impellers are provided with blades made from high quality pressure die cast aluminium
A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
The Elta Compact SCPP is a 1phase two stage axial fan specifically developed for high pressure requirements not suited to single stage fans. The fans have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing.
Features
Available in 3 sizes 500/560/630 all stocked
The fan can be installed at any angle
Suitable for internal and external use
500dia and 560dia suitable for speed control
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and +50°C when used with a speed controller.
Adjustable pitch aerofoil impellers are provided with blades made from high quality pressure die cast aluminium
The Elta Compact SCPP is a 1phase two stage axial fan specifically developed for high pressure requirements not suited to single stage fans. The fans have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing.
Features
Available in 3 sizes 500/560/630 all stocked
The fan can be installed at any angle
Suitable for internal and external use
500dia and 560dia suitable for speed control
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and +50°C when used with a speed controller.
Adjustable pitch aerofoil impellers are provided with blades made from high quality pressure die cast aluminium
The Compact SCD is a short cased axial fan, featuring Elta’s new high efficiency impeller, designed for duct mounting.
Both 1ph fans are suitable for speed control
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and
+50°C when used with a speed controller
Impellors hubs are die cast aluminium and the blades high quality GRP
Fans are weatherproofed
This range has a powder coated polyester epoxy paint finish in pastel beige (RAL 7032)
The Compact SCD is a short cased axial fan, featuring Elta’s new high efficiency impeller, designed for duct mounting.
Both 1ph fans are suitable for speed control
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and
+50°C when used with a speed controller
Impellors hubs are die cast aluminium and the blades high quality GRP
Fans are weatherproofed
This range has a powder coated polyester epoxy paint finish in pastel beige (RAL 7032)
The Compact SCP is a plate axial fan from Elta featuring their new high efficiency impeller. The fan design, construction and finish provides for a strong durable and weatherproofed range.
All 1ph fans are suitable for speed control
An all metal fan casing and guard provide a long lasting and robust construction
Impellors hubs are die cast aluminium and the blades high quality GRP
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and
+50°C when used with a speed controller
Fans have a powder coated polyester epoxy paint finish in pastel beige (RAL 7032)
The Compact SCP is a plate axial fan from Elta featuring their new high efficiency impeller. The fan design, construction and finish provides for a strong durable and weatherproofed range.
All 1ph fans are suitable for speed control
An all metal fan casing and guard provide a long lasting and robust construction
Impellors hubs are die cast aluminium and the blades high quality GRP
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and
+50°C when used with a speed controller
Fans have a powder coated polyester epoxy paint finish in pastel beige (RAL 7032)
The Compact SCP is a plate axial fan from Elta featuring their new high efficiency impeller. The fan design, construction and finish provides for a strong durable and weatherproofed range.
All 1ph fans are suitable for speed control
An all metal fan casing and guard provide a long lasting and robust construction
Impellors hubs are die cast aluminium and the blades high quality GRP
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and
+50°C when used with a speed controller
Fans have a powder coated polyester epoxy paint finish in pastel beige (RAL 7032)
The Compact SCP is a plate axial fan from Elta featuring their new high efficiency impeller. The fan design, construction and finish provides for a strong durable and weatherproofed range.
All 1ph fans are suitable for speed control
An all metal fan casing and guard provide a long lasting and robust construction
Impellors hubs are die cast aluminium and the blades high quality GRP
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and
+50°C when used with a speed controller
Fans have a powder coated polyester epoxy paint finish in pastel beige (RAL 7032)
The Compact SCP is a plate axial fan from Elta featuring their new high efficiency impeller. The fan design, construction and finish provides for a strong durable and weatherproofed range.
All 1ph fans are suitable for speed control. This fan needs a transformer controller; 149-TC110.
An all metal fan casing and guard provide a long lasting and robust construction
Impellors hubs are die cast aluminium and the blades high quality GRP
Fans are suitable for operating temperatures between -20°C and +70°C fixed speed and -20°C and
+50°C when used with a speed controller
Fans have a powder coated polyester epoxy paint finish in pastel beige (RAL 7032)
Brook Crompton are one of the leading motor manufacturers in the UK, this Series 3000 single phase starter offers push button on and off, with overload protection. Overload protection gives extra safety by automatically stopping the fan when the full load current is exceeded, unlike fuse protection which is designed to protect life and usually blows when the fan has already failed. Overload protection can protect the fan from failure from such events as foreign bodies (such as a chef’s hat or paper towels jamming the fan blades
We would recommend this starter is used for Commercial or Industrial applications, it’s not usually used for domestic applications.
This standard starter has a full load range of 0.1 to 12 amps.
Max Kw 5.5
Please advise the full load of the fan when ordering
500mm dia x 500mm long straight through silencer (generally reduces a fan noise level by 7-10dB (A)* Can be supplied to either bolt directly to any manufacturer of cased axial or with spigots to mount inline with ducting.
The addition of this silencer to a system will act in the same way a silencer does on a car, so if you've ever heard a car with no silencer fitted, this gives you an idea of the impact a silencer can have on a system.
Please Note - for a straight through silencer to work to have the maximum impact on a system, a silencer should be fixed either side of the fan, this will give 3 benefits to the overall noise level of the system.
1. System side (usually the noise level inside a building) noise level is reduced
2. Atmospheric side (usually the noise level outside a building) noise level is reduced
3. The breakout from the fan is reduced, this could be a big factor depending where the fan is fitted, such as a false ceiling in a class room or office area
*Noise is a complicated medium to get right, if in doubt or you have specific target levels to achieve, please contact us via any means you feel comfortable with and we'll find a solution to your problem
400mm dia x 400mm long straight through silencer (generally reduces a fan noise level by 7-10dB (A)* Can be supplied to either bolt directly to any manufacturer of cased axial or with spigots to mount inline with ducting.
The addition of this silencer to a system will act in the same way a silencer does on a car, so if you've ever heard a car with no silencer fitted, this gives you an idea of the impact a silencer can have on a system.
Please Note - for a straight through silencer to work to have the maximum impact on a system, a silencer should be fixed either side of the fan, this will give 3 benefits to the overall noise level of the system.
1. System side (usually the noise level inside a building) noise level is reduced
2. Atmospheric side (usually the noise level outside a building) noise level is reduced
3. The breakout from the fan is reduced, this could be a big factor depending where the fan is fitted, such as a false ceiling in a class room or office area
*Noise is a complicated medium to get right, if in doubt or you have specific target levels to achieve, please contact us via any means you feel comfortable with and we'll find a solution to your problem
560mm dia x 560mm long straight through silencer (generally reduces a fan noise level by 7-10dB (A)* Can be supplied to either bolt directly to any manufacturer of cased axial or with spigots to mount inline with ducting.
The addition of this silencer to a system will act in the same way a silencer does on a car, so if you've ever heard a car with no silencer fitted, this gives you an idea of the impact a silencer can have on a system.
Please Note - for a straight through silencer to work to have the maximum impact on a system, a silencer should be fixed either side of the fan, this will give 3 benefits to the overall noise level of the system.
1. System side (usually the noise level inside a building) noise level is reduced
2. Atmospheric side (usually the noise level outside a building) noise level is reduced
3. The breakout from the fan is reduced, this could be a big factor depending where the fan is fitted, such as a false ceiling in a class room or office area
*Noise is a complicated medium to get right, if in doubt or you have specific target levels to achieve, please contact us via any means you feel comfortable with and we'll find a solution to your problem
315mm dia x 315mm long straight through silencer (generally reduces a fan noise level by 7-10dB (A)* Can be supplied to either bolt directly to any manufacturer of cased axial or with spigots to mount inline with ducting.
The addition of this silencer to a system will act in the same way a silencer does on a car, so if you've ever heard a car with no silencer fitted, this gives you an idea of the impact a silencer can have on a system.
Please Note - for a straight through silencer to work to have the maximum impact on a system, a silencer should be fixed either side of the fan, this will give 3 benefits to the overall noise level of the system.
1. System side (usually the noise level inside a building) noise level is reduced
2. Atmospheric side (usually the noise level outside a building) noise level is reduced
3. The breakout from the fan is reduced, this could be a big factor depending where the fan is fitted, such as a false ceiling in a class room or office area
*Noise is a complicated medium to get right, if in doubt or you have specific target levels to achieve, please contact us via any means you feel comfortable with and we'll find a solution to your problem
355mm dia x 355mm long straight through silencer (generally reduces a fan noise level by 7-10dB (A)* Can be supplied to either bolt directly to any manufacturer of cased axial or with spigots to mount inline with ducting.
The addition of this silencer to a system will act in the same way a silencer does on a car, so if you've ever heard a car with no silencer fitted, this gives you an idea of the impact a silencer can have on a system.
Please Note - for a straight through silencer to work to have the maximum impact on a system, a silencer should be fixed either side of the fan, this will give 3 benefits to the overall noise level of the system.
1. System side (usually the noise level inside a building) noise level is reduced
2. Atmospheric side (usually the noise level outside a building) noise level is reduced
3. The breakout from the fan is reduced, this could be a big factor depending where the fan is fitted, such as a false ceiling in a class room or office area
*Noise is a complicated medium to get right, if in doubt or you have specific target levels to achieve, please contact us via any means you feel comfortable with and we'll find a solution to your problem
630mm dia x 630mm long straight through silencer (generally reduces a fan noise level by 7-10dB (A)* Can be supplied to either bolt directly to any manufacturer of cased axial or with spigots to mount inline with ducting.
The addition of this silencer to a system will act in the same way a silencer does on a car, so if you've ever heard a car with no silencer fitted, this gives you an idea of the impact a silencer can have on a system.
Please Note - for a straight through silencer to work to have the maximum impact on a system, a silencer should be fixed either side of the fan, this will give 3 benefits to the overall noise level of the system.
1. System side (usually the noise level inside a building) noise level is reduced
2. Atmospheric side (usually the noise level outside a building) noise level is reduced
3. The breakout from the fan is reduced, this could be a big factor depending where the fan is fitted, such as a false ceiling in a class room or office area
*Noise is a complicated medium to get right, if in doubt or you have specific target levels to achieve, please contact us via any means you feel comfortable with and we'll find a solution to your problem
710mm dia x 710mm long straight through silencer (generally reduces a fan noise level by 7-10dB (A)* Can be supplied to either bolt directly to any manufacturer of cased axial or with spigots to mount inline with ducting.
The addition of this silencer to a system will act in the same way a silencer does on a car, so if you've ever heard a car with no silencer fitted, this gives you an idea of the impact a silencer can have on a system.
Please Note - for a straight through silencer to work to have the maximum impact on a system, a silencer should be fixed either side of the fan, this will give 3 benefits to the overall noise level of the system.
1. System side (usually the noise level inside a building) noise level is reduced
2. Atmospheric side (usually the noise level outside a building) noise level is reduced
3. The breakout from the fan is reduced, this could be a big factor depending where the fan is fitted, such as a false ceiling in a class room or office area
*Noise is a complicated medium to get right, if in doubt or you have specific target levels to achieve, please contact us via any means you feel comfortable with and we'll find a solution to your problem
710MM FLEXIBLE CONNECTION

710mm Flexible connection, used to fit to Flanges (with spigots), Silencers (with spigots) or spiral ducting.
A flexible connection is used to isolate the fan from the system to prevent vibration transfer and helps minimise noise transfer through fixings or structures.
It can also be used to simplify installation by bridging any small gaps between sections of the installation, for example the gap between a fan and the ductwork
450MM DIA FLANGE

450mm dia Flange used to bolt directly to the Fan, as part of a full ancillary package or for the fan to mount inline in ducting
Can also be used to fix directly to a Silencer
Can also be used to fix directly to ducting
Hot dipped Galvanised after manufacture
EL101 Elta fan speed controller

The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
- 149-EL21 suitable for a maximum full load of 1.5 amps
- 149-EL31 suitable for a maximum full load of 3 amps
- 149-EL31TK suitable for a maximum full load of 3 amps *
- 149-EL41 suitable for a maximum full load of 4 amps
- 149-EL61 suitable for a maximum full load of 6 amps
- 149-EL61TK suitable for a maximum full load of 6 amps *
- 149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
- Flakt Woods
- Ziehl Abegg
- Elta
- Helios
- Solar and Palau
- Nuaire
- Systemair
- Vent-Axia
- Roof Units
Not sure if your fan is suitable? just ask and we can check for you
315 MOUNTING FEET

Supplied in pairs
315mm Mounting Foot, used to fit directly to the fan as part of a full ancillary package
The Mounting Foot can be used to mount the fan in the horizontal or vertical position
Usually used in conjunction with Anti Vibration Mounts
Can also be used to fit directly to Silencers with or without Anti Vibration Mounts
315MM DIA FLANGE

315mm dia Flange used to bolt directly to the Fan, as part of a full ancillary package or for the fan to mount inline in ducting
Can also be used to fix directly to a Silencer
Can also be used to fix directly to ducting
Hot dipped Galvanised after manufacture
315MM DIA FLANGE

suits any manufacturer of fans
suits any manufacturer of fans315mm dia Flange used to bolt directly to any manufacturer of Fans, as part of a full ancillary package or for the fan to mount inline in ducting.
This flange is unique because it is designed to fix to UK and European PCD detail, meaning this flange will fix to any manufacturers fans
Can also be used to fix directly to a Silencer
Can also be used to fix directly to ducting
Manufactured from pre Galvanised sheet
400MM DIA FLANGE

400mm dia Flange used to bolt directly to the Fan, as part of a full ancillary package or for the fan to mount inline in ducting
Can also be used to fix directly to a Silencer
Can also be used to fix directly to ducting
Hot dipped Galvanised after manufacture
400MM FLEXIBLE CONNECTION

A Louvre Shutter is a gravity type shutter which can be used to terminate and weather extract systems. When the fan is running the plastic blades will open allowing the air to be extracted from the system, and when the fan is not running will be closed, this helps to prevent back draughts and water ingress
The shutter is commonly used to terminate systems where a plate mounted fan has been fitted internally, and used for extraction
Louvre shutters are usually either mounted to an external wall or at the end of a galvanised box to terminate an extract system
This Louvre shutter can only be used on EXTRACT systems, for SUPPLY systems please contact us direct, by any means you feel comfortable with and we will advise what should be used to suit your application
It can also be used to simplify installation by bridging any small gaps between sections of the installation, for example the gap between a fan and the ductwork
400MM MOUNTING FEET

Supplied in pairs
400mm Mounting Foot, used to fit directly to the fan as part of a full ancillary package
The Mounting Foot can be used to mount the fan in the horizontal or vertical position
Usually used in conjunction with Anti Vibration Mounts
Can also be used to fit directly to Silencers with or without Anti Vibration Mount
EL31 Elta fan speed controller

The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
-
149-EL21 suitable for a maximum full load of 1.5 amps
-
149-EL31 suitable for a maximum full load of 3 amps
-
149-EL31TK suitable for a maximum full load of 3 amps *
-
149-EL41 suitable for a maximum full load of 4 amps
-
149-EL61 suitable for a maximum full load of 6 amps
-
149-EL61TK suitable for a maximum full load of 6 amps *
- 149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
-
Flakt Woods
-
Ziehl Abegg
-
Elta
-
Helios
-
Solar and Palau
-
Nuaire
-
Systemair
-
Vent-Axia
- Roof Units
Not sure if your fan is suitable? just ask and we can check for you
EL41 Elta fan speed controller

The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
- 149-EL21 suitable for a maximum full load of 1.5 amps
- 149-EL31 suitable for a maximum full load of 3 amps
- 149-EL31TK suitable for a maximum full load of 3 amps *
- 149-EL41 suitable for a maximum full load of 4 amps
- 149-EL61 suitable for a maximum full load of 6 amps
- 149-EL61TK suitable for a maximum full load of 6 amps *
- 149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
- Flakt Woods
- Ziehl Abegg
- Elta
- Helios
- Solar and Palau
- Nuaire
- Systemair
- Vent-Axia
- Roof Units
Not sure if your fan is suitable? just ask and we can check for you
EL61TK Elta fan speed controller

The EL range of electronic fan speed controllers manufactured by Elta. This range of fan speed controllers can be used with any Fan / Motor which is single phase – 240 volts and speed controllable using either 2 or 3 wire control (+earth).
-
149-EL21 suitable for a maximum full load of 1.5 amps
-
149-EL31 suitable for a maximum full load of 3 amps
-
149-EL31TK suitable for a maximum full load of 3 amps *
-
149-EL41 suitable for a maximum full load of 4 amps
-
149-EL61 suitable for a maximum full load of 6 amps
-
149-EL61TK suitable for a maximum full load of 6 amps *
- 149-EL101 suitable for a maximum full load of 10 amps
* TK Versions offer means of motor protection via motor thermal Contact.
The EL range of fan speed controllers can be used with any manufacturers fans / motors which are single phase and suitable for speed control via 2 or 3 wires (+earth) including
-
Flakt Woods
-
Ziehl Abegg
-
Elta
-
Helios
-
Solar and Palau
-
Nuaire
-
Systemair
-
Vent-Axia
- Roof Units
Not sure if your fan is suitable? just ask and we can check for you
FWX 2 Inverter speed controller

inverter speed controller
FWX 3 INVERTER SPEED CONTROLLER